Urgent leak or storm damage? Call 01473 974194 - answered day and nightUrgent leak? Call 01473 974194
Ipswich Roofing Specialists
01473 974194 Get a Quote →

Lead Work in Claydon

Ipswich Roof carries out lead flashing and weathering work in Claydon, using the right material and the right code weight for every location on the roof.

Urgent leak or storm damage?

Call any time. Calls are answered day and night and passed straight to our roofers.

Call now: 01473 974194
Lead work · Claydon

Expert Lead work
in Claydon

Choosing the Right Material for Lead Work - What Your Options Actually Are

When lead flashing fails or a new section needs installing, homeowners in Claydon sometimes ask whether they have to use lead at all. The honest answer is that lead is still the best material for most applications - but there are alternatives worth knowing about, and each has real trade-offs. This page sets out the options clearly so you can make an informed decision rather than simply accepting whatever a roofer suggests.

Lead - The Standard Choice and Why

Milled lead sheet has been used in roofing for centuries, and its durability is not marketing. Correctly specified and dressed, lead flashing will typically outlast the tiles around it by decades. It is malleable enough to be formed precisely around complex shapes - the curved base of a chimney stack, the upstand of a dormer, the angle of a valley - and it holds that shape permanently once dressed.

Lead is sold in code weights, which refer to the thickness of the sheet. The higher the code, the thicker and heavier the lead. Codes commonly used in roofing range from Code 3 (the lightest, approximately 1.32mm thick) through to Code 8 (approximately 3.55mm). The correct code for each location is specified in BS EN 12588 and by the Lead Sheet Association. Using the wrong code - typically a lighter weight to cut material costs - is one of the most common reasons lead work fails prematurely.

  • Code 3: Soakers beneath step flashings only. Too thin for exposed surfaces.
  • Code 4: Vertical flashings in sheltered positions, chimney aprons.
  • Code 5: Step and cover flashings, dormer flashings, chimney back gutters in most situations.
  • Code 6: Valley gutters, parapet gutters, flat roof upstands, back gutters on large chimney stacks.
  • Code 7 and 8: Larger valley and parapet gutters, flat roofs requiring heavy-duty weathering.

When getting a quote for lead work, ask the roofer what code weight they intend to use and why. If the answer is vague or they cannot tell you, that is worth noting.

Alternatives to Lead - Honest Pros and Cons

Lead is not the only option. Several alternative flashing materials are available, and some roofers use them routinely. Here is an honest assessment of each.

Aluminium Flashing

Aluminium flashing is lighter than lead and less expensive. It comes in rolls and can be formed around shapes in a similar way. Pre-painted aluminium is available in colours that approximate the grey of weathered lead.

Pros: Lower material cost. Lighter weight. Does not need to be cut from sheet - supplied in ready-sized rolls for common applications.

Cons: Less malleable than lead, so more difficult to dress neatly around complex profiles. Aluminium and certain masonry mortars can react chemically, accelerating corrosion. Aluminium in direct contact with copper pipework or copper-based treatments will corrode rapidly. Lifespan is generally shorter than correctly specified lead.

Self-Adhesive Flashing Tape (Torch-Free)

Butyl rubber and lead-faced self-adhesive tapes are widely available and are used by some contractors for small repairs, particularly where a short-term fix is needed quickly.

Pros: Fast to apply. No special tools needed. Useful for emergency or temporary repairs.

Cons: Not a permanent solution. Adhesion degrades with UV exposure and thermal cycling. Sealant-based tapes in particular tend to crack and peel within a few years. For a chimney, dormer or valley, tape is not an appropriate replacement for properly dressed lead and its use should be questioned on any quote for lasting work.

Lead-Coated Copper

Lead-coated copper combines a copper substrate with a lead surface. It is used mainly in conservation and heritage work where planners require a specific appearance.

Pros: Extremely durable. Acceptable to conservation officers where lead itself is required for appearance but weight is a concern.

Cons: Significantly more expensive than plain lead. Specialist in its application. Not necessary or cost-effective for standard domestic work.

EPDM Rubber - Not a Flashing Material

EPDM rubber is used for flat roofing membranes and is an excellent material in that application. However, it is not a flashing material for pitched roof abutments, chimneys or dormers. Some homeowners see it mentioned in roofing discussions and ask about it; for lead work applications, it is not the right product.

Which Material Should You Choose?

For the vast majority of chimney flashings, dormer flashings, valley gutters and wall abutments, correctly specified milled lead sheet remains the best choice. It is workable, durable and proven. Alternatives may be appropriate in specific circumstances - a budget repair ahead of a planned extension, for example - but they should be presented to you as a conscious trade-off, not as an equivalent to lead. A roofer using lead tape where Code 5 lead should be dressed is cutting costs at your expense.

How Lead Is Fixed in Place

Understanding the fixing method helps you ask whether a job has been done properly. Step and cover flashings are chased into the mortar joints of brickwork using lead wedges, then pointed with a suitable flexible mortar. Apron flashings and back gutters are fixed at their top edge and dressed down over the roof surface. Valley gutters are laid over the underlying tile battens or boarding with clips at intervals to allow for movement.

The critical principle is that lead must be free to move slightly with temperature changes. Fixing it rigidly at both ends - or using cement mortar that grips it tight against the brick - will cause it to crack within a few years. Each sheet should be laid in bays no longer than 1.5 metres, with a small step overlap between each bay to allow thermal movement without stress.

What a Proper Lead Work Quote Should Include

When you receive a quote for lead work in Claydon or the surrounding area, it should specify:

  • The location of the work and what is being replaced or repaired
  • The code weight of lead to be used at each location
  • Whether old lead will be stripped and replaced, or additional lead dressed over existing
  • How the flashing will be fixed and pointed
  • Disposal of old materials

A quote that says only "repair chimney flashing - £X" without those specifics makes it very difficult to compare against another quote or to confirm afterwards that the right work was done.

Lead Work as Part of a Wider Roof Check

Lead flashing is just one part of what keeps a roof watertight. When we are working on a chimney or dormer in Claydon, we check the surrounding tile or slate work, the ridge and hip mortar, and the condition of the felt beneath where it is visible. If gutters or fascias are showing signs of wear at the same time, that is worth knowing about. We carry out the full range of roof repairs, chimney refurbishment, Velux and skylight work, and fascia, soffit and guttering replacement.

Ready to Get Your Lead Work Quoted?

Call us to arrange a roof survey in Claydon. We will tell you what code weight is needed where, what the options are, and give you a clear breakdown so you can make a well-informed decision about the work.

Why choose Ipswich Roof?

  • Free survey and itemised quote
  • Fixed price - no surprises
  • Local team

Get your free quote

No obligation · We'll call you to arrange a free visit

By submitting you agree to being contacted about your enquiry. No spam, ever.

Urgent leak or storm damage?

Call any time. Calls are answered day and night and passed straight to our roofers.

Call now: 01473 974194