If you are arranging fascia, soffit and guttering replacement in Martlesham, knowing what a proper installation looks like from start to finish helps you judge whether the work has been done correctly.
Call any time. Calls are answered day and night and passed straight to our roofers.
Replacing fascias, soffits and guttering is a single connected job because all three elements come off and go back on together. Doing them separately - for example, fitting new guttering on old failing fascias - means the gutter fixings will not hold for long. A complete replacement deals with the whole system in one visit and leaves nothing to fail in the short term.
The work covers the fascia boards running along the roof edge, the soffit boards sitting beneath them, and the guttering that carries rainwater away from the roof. On a typical semi-detached house the job takes one to two days; on a larger detached property or one with complex rooflines it takes longer. What follows is a step-by-step account of how the work should be carried out.
Before any scaffolding goes up or materials are ordered, the existing condition needs to be checked properly. A look from ground level is not enough; the fascia, soffit and rafter feet need to be inspected at close range.
The key questions at this stage are: Is the timber behind the fascia still sound? Are the rafter feet - the ends of the roof timbers that the fascia is fixed to - firm and dry, or have they been affected by moisture? Is there any evidence of previous water ingress that has tracked inward? Are the existing soffit ventilation provisions adequate and in the right positions?
Any contractor who gives you a final price without getting eyes on the rafter feet is pricing on assumptions. Those assumptions may be correct, but they may not be, and the difference matters.
Fascia, soffit and gutter work is done from ladders or scaffolding, depending on the height of the property and the complexity of the roofline. A standard two-storey house is usually manageable from ladders with stand-offs to protect the guttering. Anything taller, or with hips and valleys that require working at different angles, is safer and faster from a scaffold platform.
Where scaffolding is used, it should be erected by a competent scaffolder and inspected before work begins. This is not a detail to skip on grounds of cost.
The old guttering comes off first, followed by the fascia boards and then the soffits. On houses with original cast iron guttering, this stage takes considerably longer than on uPVC systems; cast iron sections are heavy and need to be lowered carefully rather than dropped.
Once the boards are off, the rafter feet and the wall plate behind the soffit are exposed and can be inspected properly. This is the point where any problems that were hidden behind the old boards become visible. Soft or rotten rafter feet need to be treated and, where structurally necessary, spliced or sistered before new boards are fixed. Skipping this step and fixing new fascias into compromised timber is one of the most common reasons for a replacement failing ahead of its expected life.
Old materials should be removed from the property and disposed of responsibly. A skip or trade waste vehicle is the normal approach; bagged and left on site is not acceptable practice.
Exposed rafter feet and any bare timber at the wall plate should be treated with a preservative before new boards go on. This applies even where the timber looks sound; it has been exposed to some level of moisture over the years and treatment at this stage adds protection before it is enclosed again.
Where any rafter feet have suffered decay, a decision needs to be made about the extent of the work. Minor decay at the very tip of the rafter foot can sometimes be cut back to sound wood; more extensive decay may require a structural splice. This is the stage at which an honest assessment matters most, because once the new boards are on the rafter ends are inaccessible again.
Soffits are fitted before fascias because the fascia then covers the upper edge of the soffit board. The soffit sits between the wall and the fascia and is fixed to a batten on the wall at one side and to the rafter feet or a continuous bearer at the other.
Ventilation is built into this stage. Cold roofs require airflow into the roof space to prevent condensation on the underside of the roof deck. The standard approach is to use a soffit board with factory-cut ventilation slots or to install a separate continuous vent strip. The size and positioning of the ventilation should comply with building regulations. If the previous installation had vented soffits, the replacement must too.
Fascia boards are fixed directly to the rafter feet. They should be long enough to avoid unnecessary joints, since every joint is a potential point of water ingress if it moves or the sealant fails. Where joints are unavoidable, they should fall at a rafter foot so both ends of the board are fixed and supported.
The fascia must sit flush with the underside of the bottom course of tiles or slates, so that rainwater running off the roof surface falls directly into the gutter behind it and not behind the fascia board. This is a detail that has to be checked as each board goes on, not assumed.
Any cut ends or joints in uPVC should be sealed with a compatible sealant; any cut ends in timber should be primed on site before fixing.
Guttering is hung on brackets fixed through the fascia board into the rafter feet behind it. The fall - the slope of the gutter from one end to the downpipe - should be between 1 in 350 and 1 in 600 as a general guide; enough to drain freely without being so steep that it looks visually wrong from the front of the house.
On a long run of guttering, this fall means the gutter sits lower at the downpipe end than at the far end, sometimes by several centimetres on a long elevation. Getting this right requires marking the bracket positions before any fixing goes in, not simply running the gutter level by eye.
Joint connections between sections should be fitted with the correct union clips and sealed where the manufacturer specifies. Downpipes should be fixed to the wall with pipe brackets at no more than 1.8 metre intervals and should discharge cleanly into the drain or gulley below without splashing back against the wall.
Once the guttering is hung, it should be tested before the team leaves site. Running water from a hose along the highest point of each run confirms the fall is correct, that joints are not leaking, and that the downpipe is discharging properly. Any adjustments to bracket heights or joint sealant should happen now, not at the next heavy rainfall.
The site should be cleared of all removed materials, fixings and packaging. A clean site at the end of the job is a reasonable minimum expectation.
We work across Martlesham, nearby Kesgrave, Felixstowe and the surrounding area through to Ipswich. If you are unsure about the condition of your existing boards or guttering, call us to arrange a survey at roof level so we can give you an accurate picture of what the work involves before any decisions are made.
No obligation · We'll call you to arrange a free visit
Call any time. Calls are answered day and night and passed straight to our roofers.